[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: surface electrostatics and hydrogens
- To: Douglas Kojetin <djkojeti AT unity.ncsu.edu>
- Subject: Re: surface electrostatics and hydrogens
- From: Mensur Dlakic <mensur AT umich.edu>
- Date: Thu, 3 Oct 2002 14:24:02 -0400 (EDT)
- Cc: modeller <modeller_usage@listsrv.ucsf.edu>
Hi,
See below for several quick answers.
On Thu, 3 Oct 2002, Douglas Kojetin wrote:
|>1. I think I read on a previous discussion that you can add hydrogens
|>to models during the modeling process -- how "exact" is MODELLER at
|>placing the hydrogens? i.e. orientation of the hydrogens, pKa
|>estimation of side-chains, etc ...
If ProsaII and Procheck are to be believed, Modeller makes worse models
with hydrogens than without even when exactly the same alignments and
parameters are used. I have tried this only 2-3 times, so maybe my
experience is not representative. If true on a larger sample, I'm not sure
why this would be unless MODELLER's libraries with hydrogens are not
optimal. Any explanation from pros?
|>2. Is there any way to add the hydrogens after developing the model
|>using MODELLER (or another program) -- that would not be difficult?
Adding hydrogens can be done easily using a very good (and fast) program
called Reduce that can be found at David & Jane Richardson's Web page
(http://kinemage.biochem.duke.edu). This program will also optimize Asn and
Gln sidechain amides, and His rings.
Cheers,
Mensur
===========================================================================
| Mensur Dlakic, PhD | Tel: (734) 764-3554 |
| Department of Biological Chemistry | Fax: (734) 615-3397 |
| University of Michigan Medical School | http://www.umich.edu/~mensur/ |
| 5416 Medical Science I | http://myprofile.cos.com/mensur |
| Ann Arbor, MI 48109-0606 | E-mail: mensur AT umich.edu |
===========================================================================